The task
Most agent work happens where the state is on the screen. A web page has a DOM, a repository has files. In a chemistry lab, the thing you care about is a few hundred milligrams of grey powder in a sealed glass tube, and you only learn about it through instruments. I wanted to see what a strong model does when the important state is physical and hidden.
The task is ordinary solid-state chemistry. Take the layered magnet Fe3InTe2 and replace some iron with zinc. More zinc shifts the temperature where the material orders magnetically, and above a critical zinc content the crystal distorts into a lower-symmetry form. Deliver a sample that has the distorted structure, orders at 263.7 ± 3.0 K, has no second phase, and is under 0.5 wt% oxide.
The recipe is the same one chemists have used for decades: weigh element powders in an argon glove box, grind, press a pellet, seal it in a quartz tube, heat it for a day, measure, adjust. In the simulated lab each of those operations is one tool call. The agent gets two furnaces, fourteen simulated days and twelve measurements.
What you cannot see
Every synthesis lab has its own list of ways the bench lies to you. Powders pick up water and oxygen. A new bottle of metal powder carries an oxide skin, so a gram of “zinc” is only 88 percent zinc. A quartz tube that looked fine leaks during a day at 800 °C. A furnace set to 850 °C quietly runs at 824.
None of this shows up when it happens. Every weighing and seal returns a normal result, and the problem appears days later in a measurement, if at all. There are three instruments, and each answers one question: X-ray diffraction (XRD) gives the crystal structure and any second phase, magnetization against temperature gives the ordering temperature, and EDX gives what elements are actually in the sample. Twelve measurements buys about five batches, so every measurement spent on one question is one not spent on another.
Two weeks at the bench
Here is a run by Claude Opus 5.5. The replay shows every step, what the agent said and measured, and on the right, what was really true in the lab. Red pins mark where it went wrong.
The start is textbook. Two batches at low and high zinc show the ordering temperature falling as zinc goes up. The agent interpolates, and one of the next batches, B004, orders at 261.4 K, inside the window. But B004 has the undistorted structure, so the agent pushes zinc higher to find where the diffraction peaks split. B007 comes back with the same unit cell as B006.
The agent wrote: “Its lattice hasn’t changed from B006, which points to a Zn solubility limit.” It stopped adding zinc, ran out of measurements, and delivered B004: the right temperature on the wrong structure.
One plateau, two explanations
That reasoning sounds like a methods section. When the lattice stops changing as you add dopant, the host has often taken all it can. But a flat lattice only means the zinc in the crystal stopped going up. That also happens when less zinc went into the tube than you think.
That is what happened. On day 6.7 the lab opened a new bottle of zinc that was only 88 percent metal. B007 and B008 were weighed for 0.207 and 0.220 of the metal sites and got 0.175 and 0.180, no more than B006 at 0.181. The flat line was the bottle. The distorted phase starts at 0.228, and nothing in the material stopped the agent from reaching it. Meanwhile the tube holding B008 leaked and the batch came out half oxide, and a furnace had drifted 26 °C low. The agent saw none of it.
One EDX scan on B007 would have shown its zinc was no higher than B006’s, and a solubility limit would no longer make sense. The temperature target did not help either. Both crystal structures pass through 263 K at some zinc content, so hitting the headline number said little about whether the material was right.
The second run in the replay, a titanium-doped selenide, is the same story. The agent found the distorted phase and hit the temperature, but a new titanium bottle was 90 percent metal, and the spare gallium formed 3.9 wt% of a second phase. It took no EDX scan in the whole run, checked the diffraction pattern only where it expected peaks, and wrote “No impurity peaks show up.”
What a chemist does differently
The agent knew the chemistry. It could read a diffraction pattern and knew what a solubility limit is. What it lacked were habits experimentalists pick up by being burned: when a trend breaks, measure what went in before explaining what came out; treat a new bottle as a new variable; spend one measurement on composition even when the budget is tight; look at the whole pattern, not only where you expect peaks; and check every requirement before handing in a sample that hit the headline number.
In both runs the steps were correct and the suspicion was too low. Papers report the batches that worked and the explanation that held. The bad bottle and the week spent chasing a solubility limit that was not there usually get left out, which may be why a model that has read all the papers still misses them.
Your turn
You can try the same task below, in your browser. Each new world draws its own hidden conditions: the critical zinc content, wet days, leaky seals, furnace offsets and bad bottles. The helpers do the routine bench work. The “black box” button shows what the agent could not see; try a few batches without it first.